System Diagnostics
 |
 |
| Clamp on D/C meter |
D/C voltage probe & diagnostic tool |
 |
|
| Wind-Up Volt Meter |
|
D/C Voltage Probe & Diagnostics Tool
Features
- Available in 12 and 24 volt versions
Product information
At first glance this low cost D/C voltmeter looks like any other one available anywhere, however, on close inspection you will see it is not. Standard voltage probes only go to 14 volts and are unable to inform you if the advanced charging cycle is in progress or a system has failed and is overcharging your system. The extra two LEDs re preset to give more useful information than the very limited standard ones. This is a Sterling product and is not available anywhere else.
D/C Clamp Meter
Electrical specification
- D/C volage 0 – 200 volts overload protection 600V
- A/C voltage 0 – 500 volts overload protection 600V
- D/C current 0 – 200 amps overload protection 300A
- A/C current 0 – 200 amps overload protection 300A
- Resistance 0 -200 ohms overload protection 400V
Data hold function
- A/C frequency response from 40 – 400 Hz
- A/C speck tested on sine wave 50/60 Hz
Wind Up Multimeter
Do you ever find yourself needing a multimeter , which you know you have somewhere and when you find it the batteries are flat, well never again, this new product has no batteries so you can leave it as long as you like, simple wind the handle 2 times for about 2 mins use, winding for about 10 seconds will give about 10 minutes of use. The high quality extremely well equipped with all the features and functions required for general use.
General specifications
Display: 46 x 23mm large LCD display
Measurement: AC, ACA, DCV, DCA, ohms, continuity beeper, Hz %, capacitance, diode, data hold.
Range selection auto ranging with manual selecting
Data hold to freeze the display reading
Dimensions 152 x 78 x 45 mm
Weight 350 g
Includes Red and Black test leads plus instruction m
Electrical Specification
- D/C voltage:
Range Volts 400.0 my - 1000 v D/C;
Accuracy +/- (1% + 3d);
Input impedance 10 M ohm
- D/C & A/C current:
10 A – 400 uA;
Overload Protection Fuse
- Ohms: 400-40 M ohm
- Capacitance: 40nF-100 uF
- Frequency: 4Hz-4MHz
- Diode (forward voltage, VF);
Range 4V DC; Test voltage 1.6 v DC; Test current 1 +/- 0.6 amps
- Continuity beeper: beep if measured resistance less than 100 ohm; response time < 100 ms
Technical information
| DC Volts |
Size |
Weight |
Code |
| 12V |
100 x 20 x 15mm |
0.25kg |
TM12V |
| 24V |
100 x 20 x 15mm |
0.25kg |
TM24V |
| Clamp |
160 x 35 x 25mm |
0.5kg |
CLAMP1 |
| Wind Up Multimeter |
152 x 78 x 45mm |
0.35kg |
WUVM |
Ordering information
|